Перевод: с английского на русский

с русского на английский

МЭК 60034-1-2004

  • 1 cyclic duration factor

    1. продолжительность включения
    2. коэффициент циклической продолжительности включения

     

    коэффициент циклической продолжительности включения
    -

    ГОСТ Р 52776-2007( МЭК 60034-1-2004)

    EN

    cyclic duration factor
    the ratio between the period of loading, including starting and electric braking, and the duration of the duty cycle, expressed as a percentage
    [IEV number 411-51-09]

    FR

    facteur de marche
    rapport de la période de fonctionnement en charge, y compris le démarrage et le freinage électrique, à la durée du cycle de service, exprimé en pourcentage
    [IEV number 411-51-09]

    Тематики

    EN

    DE

    FR

     

    продолжительность включения
    ПВ


    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.]

    Тематики

    • электротехника, основные понятия

    Синонимы

    • ПВ

    EN

    3.11 коэффициент циклической продолжительности включения (cyclic duration factor): Отношение продолжительности работы машины с нагрузкой, включая пуск и электрическое торможение, к продолжительности рабочего цикла.

    Источник: ГОСТ Р 52776-2007: Машины электрические вращающиеся. Номинальные данные и характеристики оригинал документа

    Англо-русский словарь нормативно-технической терминологии > cyclic duration factor

  • 2 II)

    1. Общее

    F.1. Общее

    В настоящем стандарте приводится большое число общих требований, которые могут или не могут быть применены в отношении отдельной машины. Поэтому простое, без квалифицированной оценки утверждение о соответствии оборудования всем требованиям настоящего стандарта является недостоверным. Прежде чем приступить к выполнению требований настоящего стандарта, его необходимо тщательно изучить. Техническими комитетами разрабатываются стандарты на отдельные виды продукции или на отдельные продукты (тип С в СЕН) и для конкретных производителей продукции. До выхода этих стандартов следует руководствоваться настоящим стандартом посредством:

    a) установления соответствия и

    b) выбора наиболее близких понятий к требованиям соответствующих разделов, и

    c) изменения требований разделов, если необходимо там, где специфические требования на машину перекрываются другими стандартами, относящимися к данному вопросу.

    В этом случае необходимо обеспечить правильный подбор модификаций и опций без снижения уровня защиты, необходимой для машины в соответствии с оценкой рисков.

    При использовании всех трех вышеприведенных принципов рекомендуется:

    - руководствоваться соответствующими разделами и пунктами настоящего стандарта:

    1) если указано соответствие применяемой опции,

    2) если требования могут быть конкретизированы для отдельной машины или оборудования;

    - руководствоваться напрямую соответствующими стандартами, в которых требования к электрооборудованию аналогичны настоящему стандарту.

    Во всех случаях экспертизой устанавливается:

    - завершенность оценки рисков для машины;

    - прочтение и понимание всех требований настоящего стандарта;

    - правильность выбора варианта реализации требований настоящего стандарта при наличии альтернативы;

    - понимание альтернативы или специфических требований, определяемых для машины или ее эксплуатации, при отсутствии или отличии от соответствующих требований настоящего стандарта;

    - точность определения таких специфических требований.

    Приведенная на рисунке 1 блок-схема типичной машины должна быть использована в качестве отправной точки при решении данной задачи. Это определяется пунктами и разделами, имеющими отношение к специфическим требованиям к оборудованию.

    Настоящий стандарт является комплексным документом, и таблица F.1 призвана помочь в понимании применения требований настоящего стандарта к специальным машинам и установлении связей с другими стандартами по данной тематике.

    Таблица F.1 - Выбор вариантов применения требований стандарта

    Наименование раздела, пункта или подпункта

    Номер раздела, пункта или подпункта

    I)

    II)

    III)

    IV)

    Область применения

    1

    X

    ИСО 121 00 (все части) ИСО 14121 [28]

    Общие требования

    4

    X

    X

    X

    МЭК 60439

    Электрооборудование, соответствующее требованиям МЭК 60439

    4.2.2

    X

    X

    Устройство отключения питания (изолирующий распределитель)

    5.3

    X

    Цепи, на которые не распространяются общие правила по подключению к источнику питания

    5.3.5

    X

    X

    ИСО 12100 (все части)

    Предотвращение непреднамеренных пусков, изоляция

    5.4, 5.5, 5.6

    X

    X

    X

    ИСО 14118 [13]

    Защита от поражения электрическим током

    6

    X

    МЭК 60364-4-41

    Аварийное управление

    9.2.5.4

    X

    X

    ИСО 13850

    Двуручное управление

    9.2.6.2

    X

    X

    ИСО 13851 [14]

    Дистанционное управление

    9.2.7

    X

    X

    X

    Функции управления в случае отказа

    9.4

    X

    X

    X

    ИСО 14121 [28]

    Датчики положения

    10.1.4

    X

    X

    X

    ИСО 14119 [29]

    Цвета и маркировка операционного интерфейса

    10.2, 10.3, 10.4

    X

    X

    МЭК 60073

    Устройства аварийной остановки

    10.7

    X

    X

    ИСО 13850

    Устройства аварийного отключения

    10.8

    X

    Аппаратура управления, защита от внешних воздействий

    10.1.3, 11.3

    X

    X

    X

    МЭК 60529

    Идентификация проводов

    13.2

    X

    Подтверждение соответствия (испытания и проверка)

    18

    X

    X

    X

    Дополнительные требования (опросный лист)

    приложение В

    X

    X

    «X» обозначены разделы, пункты и подпункты настоящего стандарта, которые могут быть применены при следующих условиях:

    I) применение приведенных в разделе, пункте или подпункте материалов;

    II) использование дополнительных специфических требований;

    III) использование других требований;

    IV) использование других стандартов, в которых требования к электрооборудованию аналогичны настоящему стандарту.

    <2>Приложение G

    Таблица G.1 иллюстрирует сравнение поперечных сечений проводников в Американском сортаменте проволоки (AWG) с квадратными миллиметрами, квадратными дюймами и круговыми милами.

    Таблица G.1 - Сравнение размеров проводников

    Номерной размер,

    Номер диаметра

    Площадь поперечного сечения

    Сопротивление медного провода при постоянном токе при 20°С,

    Круговой мил

    мм2

    дюйм2

    0,2

    0,196

    0,000304

    91,62

    387

    24

    0,205

    0,000317

    87,60

    404

    0,3

    0,283

    0,000438

    63,46

    558

    22

    0,324

    0,000504

    55,44

    640

    0,5

    0,500

    0,000775

    36,70

    987

    20

    0,519

    0,000802

    34,45

    1020

    0,75

    0,750

    0,001162

    24,80

    1480

    18

    0,823

    0,001272

    20,95

    1620

    1,0

    1,000

    0,001550

    18,20

    1973

    16

    1,31

    0,002026

    13,19

    2580

    1,5

    1,500

    0,002325

    12,20

    2960

    14

    2,08

    0,003228

    8,442

    4110

    2,5

    2,500

    0,003875

    7,56

    4934

    12

    3,31

    0,005129

    5,315

    6530

    4

    4,000

    0,006200

    4,700

    7894

    10

    5,26

    0,008152

    3,335

    10380

    6

    6,000

    0,009300

    3,110

    11841

    8

    8,37

    0,012967

    2,093

    16510

    10

    10,000

    0,001550

    1,840

    19735

    6

    13,3

    0,020610

    1,320

    26240

    16

    16,000

    0,024800

    1,160

    31576

    4

    21,1

    0,032780

    0,8295

    41740

    25

    25,000

    0,038800

    0,7340

    49339

    2

    33,6

    0,052100

    0,5211

    66360

    35

    35,000

    0,054200

    0,5290

    69073

    1

    42,4

    0,065700

    0,4139

    83690

    50

    47,000

    0,072800

    0,3910

    92756

    Сопротивление при температурах, отличных от 20 °С, вычисляют по формуле:

    R = RI[1 + 0,00393(t - 20)],

    где RI - сопротивление при 20°С;

    R - сопротивление при температуре t°C.

    <2>Приложение Н

    Таблица Н.1

    Обозначение ссылочного международного стандарта

    Обозначение и наименование соответствующего национального стандарта

    МЭК 60034-1

    ГОСТ 28330-89 Машины электрические асинхронные мощностью от 1 до 400 кВт включительно. Общие технические требования

    МЭК 60034-5

    *

    МЭК 60034-11

    *

    МЭК 60072-1

    *

    МЭК 60072-2

    *

    МЭК 60073:2002

    ГОСТ 29149-91 Цвета световой сигнализации и кнопок

    МЭК 60309-1:1999

    ГОСТ 29146.1-91 Соединители электрические промышленного назначения. Часть 1. Общие требования

    МЭК 60364-4-41:2001

    ГОСТ Р 50571.3-94( МЭК 60364-4-41-92) Электроустановки зданий. Часть 4. Требования по обеспечению безопасности. Защита от поражения электрическим током

    МЭК 60364-4-43:2001

    ГОСТ Р 50571.5-95 (МЭК 60364-4-43-77) Электроустановки зданий. Часть 4. Требования по обеспечению безопасности. Защита от сверхтока

    МЭК 60364-5-52:2001

    ГОСТ Р 50571.15-97( МЭК 60364-5-52-93) Электроустановки зданий. Часть 5. Выбор и монтаж электрооборудования. Глава 52. Электропроводки

    МЭК 60364-5-53:2002

    *

    МЭК 60364-5-54:2002

    ГОСТ Р 50571.10-96( МЭК 60364-5-54-80) Электроустановки зданий. Часть 5. Выбор и монтаж электрооборудования. Глава 54. Заземляющие устройства и защитные проводники

    МЭК 60364-6-61:2001

    ГОСТ Р 50571.16-99 Электроустановки зданий. Часть 6. Испытания. Глава 61. Приемо-сдаточные испытания

    МЭК 604 17-DB 2002

    *

    МЭК 60439-1:1999

    ГОСТ Р 51321.1-2000 Устройства комплектные низковольтные распределения и управления. Часть 1.Устройства, испытанные полностью или частично. Общие технические требования и методы испытаний

    МЭК 60446:1 999

    *

    МЭК 60447:2004

    ГОСТ Р МЭК 60447-2000 Интерфейс человеко-машинный. Принципы приведения в действие

    МЭК 60529:1999

    ГОСТ 14254-96( МЭК 529-89) Степени защиты, обеспечиваемые оболочками (Код IP)

    МЭК 60617-06:2001

    *

    МЭК 60621-3:1979

    *

    МЭК 60664-1:1992

    *

    МЭК 60947-1:2004

    ГОСТ Р 50030.1-2007( МЭК 60947-1: 2004) Аппаратура распределения и управления низковольтная. Часть 1. Общие требования

    МЭК 60947-2:2003

    ГОСТ Р 50030.2-99( МЭК 60947-2-98) Аппаратура распределения и управления низковольтная. Часть 2. Автоматические выключатели

    МЭК 60947-5-1:2003

    ГОСТ Р 50030.5.1-2005 (МЭК 60947-5-1:2003) Аппаратура распределения и управления низковольтная. Часть 5. Аппараты и коммутационные элементы цепей управления. Глава 1. Электромеханические аппараты для цепей управления

    МЭК 60947-7-1:2002

    ГОСТ Р 50030.7.1-2000 (МЭК 60947-7-1-89) Аппаратура распределения и управления низковольтная. Часть 7. Электрооборудование вспомогательное. Раздел 1. Клеммные колодки для медных проводников

    МЭК 61082-1:1991

    *

    МЭК 61082-2:1993

    *

    МЭК 61082-3:1993

    *

    МЭК 61082-4:1996

    *

    МЭК 61140:2001

    ГОСТ Р МЭК 61140-2000 Защита от поражения электрическим током. Общие положения по безопасности, обеспечиваемой электрооборудованием и электроустановками в их взаимосвязи

    МЭК 61310 -2

    ГОСТ 28690-90 Знак соответствия технических средств требованиям электромагнитной совместимости. Форма, размеры, технические требования

    МЭК 61 310 (все части за исключением части 2)

    *

    МЭК 61 346 (все части)

    *

    МЭК 61557-3:1997

    ГОСТ Р МЭК 61557-3 2006 Сети электрические распределительные низковольтные напряжением до 1000 В переменного 1500 В постоянного тока. Электробезопасность. Аппаратура для испытаний, измерения и контроля средств защиты. Часть 3. Полное сопротивление контура

    МЭК 61 558-1: 1997

    *

    МЭК 61558-2-6

    *

    МЭК 61984:2001

    *

    МЭК 62023:2000

    *

    МЭК 62027:2000

    *

    МЭК 62061:2005

    *

    МЭК 62079:2001

    *

    ИСО 7000:2004

    *

    ИСО 12100-1:2003

    *

    ИСО 12100-2:2003

    *

    ИСО 13849-1:1999

    *

    ИСО 13849-2:2003

    *

    ИСО 13850:1996

    *

    *Соответствующий национальный стандарт отсутствует. До его утверждения рекомендуется использовать перевод на русский язык данного международного стандарта. Перевод данного международного стандарта находится в Федеральном информационном фонде технических регламентов и стандартов

    <2>Библиография

    [1] МЭК 60038:2002

    Стандартные напряжения

    [2] МЭК 60204-11:2000

    Безопасность машин. Электрическое оборудование машин. Часть 11. Требования к высоковольтному оборудованию на напряжения свыше 1000 В переменного тока или 1500 В постоянного тока, но не свыше 36 кВ

    [3] МЭК 60204-31:1996

    Электрооборудование промышленных машин. Частные требования к швейным машинам, установкам и системам

    [4] МЭК 60204-32:1998

    Безопасность оборудования. Электрооборудование промышленных  машин. Часть 32. Требования к грузоподъемным машинам

    [5] МЭК 61000-6-1:1997

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 1. Устойчивость к электромагнитным помехам в жилой, коммерческой и среде легкой индустрии

    [6] МЭК 61000-6-2:2005

    Совместимость технических средств электромагнитная. Часть 6-2. Общие требования. Устойчивость к электромагнитным помехам в промышленных зонах

    [7] СИСПР 61000-6-3:1996

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 3. Нормы эмиссии для жилых, коммерческих и среды легкой индустрии

    [8] МЭК 61000-6-4:1997

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 4. Эмиссия помех в промышленных зонах

    [9] МЭК 61000-5-2:1997

    Электромагнитная совместимость. Часть 5. Монтаж и снижение помех в проводке. Раздел 2. Заземление и скрутка

    [10] МЭК 61496-1:2004

    Безопасность машин. Электрочувствительное защитное оборудование. Часть 1. Общие требования и испытания

    [11] МЭК 61800-3:2004

    Электроприводы регулируемые. Часть 3. Требования по электромагнитной совместимости и методы испытаний

    [12] МЭК 60947-5-2:1997

    Аппараты коммутационные и управления низковольтные. Часть 5-2. Устройства управления и переключатели. Выключатели конечные Дополнение 1 (1999) Дополнение 2 (2003)

    [13] ИСО 14118:2000

    Безопасность машин. Предотвращение непредусмотренного пуска

    [14] ИСО 13851:2002

    Безопасность машин. Средства управления обоими руками. Функциональные аспекты и принципы проектирования

    [15] ИСО 14122 серия

    Безопасность машин. Средства постоянного доступа к машине

    [16]СЕНЕЛЕК НD 516 S2

    Руководство по применению гармонизированных кабелей

    [17] МЭК 60287 (все части)

    Кабели. Расчет номинальных токов нагрузок в условиях установившегося режима

    [18] МЭК 60757:1983

    Коды для обозначения цветов

    [19] МЭК 60332 (все части)

    Испытания на огнестойкость электрических и оптических кабелей

    [20] МЭК 61084-1: 1991

    Кабельные проводящие и канализирующие системы для электрического монтажа. Часть 1. Основные требования

    [21] МЭК 60364 (все части)

    Электроустановки зданий

    [22] МЭК 61557 (все части)

    Безопасность в низковольтных  системах  электроснабжения   напряжением до 1000 В переменного тока и до 1500 В постоянного тока. Оборудование для проведения испытаний, измерений и контроля исполнения защитных функций

    [23] МЭК 60228:2004

    Жилы токопроводящие изолированных кабелей

    [24] МЭК 61200-53:1994

    Устройства электрические. Часть 53. Выбор и монтаж электрооборудования. Аппаратура коммутационная и управления

    [25] МЭК 61180-2:1994

    Техника для проведения высоковольтных испытаний низковольтного электрооборудования. Часть 2. Испытательное оборудование

    [26] МЭК 60335 (все части)

    Бытовое и аналогичное ему применение электричества. Безопасность

    [27] МЭК 60269-1:1998

    Предохранители низковольтные. Часть 1. Общие требования

    [28] ИСО 14121:1999

    Безопасность машин. Принципы оценки риска

    [29] ИСО 14119:1998

    Безопасность машин. Блокировочные устройства для ограждений. Принципы конструкции и выбора

    <2>

    Источник: ГОСТ Р МЭК 60204-1-2007: Безопасность машин. Электрооборудование машин и механизмов. Часть 1. Общие требования оригинал документа

    Англо-русский словарь нормативно-технической терминологии > II)

  • 3 III)

    1. Общее

    F.1. Общее

    В настоящем стандарте приводится большое число общих требований, которые могут или не могут быть применены в отношении отдельной машины. Поэтому простое, без квалифицированной оценки утверждение о соответствии оборудования всем требованиям настоящего стандарта является недостоверным. Прежде чем приступить к выполнению требований настоящего стандарта, его необходимо тщательно изучить. Техническими комитетами разрабатываются стандарты на отдельные виды продукции или на отдельные продукты (тип С в СЕН) и для конкретных производителей продукции. До выхода этих стандартов следует руководствоваться настоящим стандартом посредством:

    a) установления соответствия и

    b) выбора наиболее близких понятий к требованиям соответствующих разделов, и

    c) изменения требований разделов, если необходимо там, где специфические требования на машину перекрываются другими стандартами, относящимися к данному вопросу.

    В этом случае необходимо обеспечить правильный подбор модификаций и опций без снижения уровня защиты, необходимой для машины в соответствии с оценкой рисков.

    При использовании всех трех вышеприведенных принципов рекомендуется:

    - руководствоваться соответствующими разделами и пунктами настоящего стандарта:

    1) если указано соответствие применяемой опции,

    2) если требования могут быть конкретизированы для отдельной машины или оборудования;

    - руководствоваться напрямую соответствующими стандартами, в которых требования к электрооборудованию аналогичны настоящему стандарту.

    Во всех случаях экспертизой устанавливается:

    - завершенность оценки рисков для машины;

    - прочтение и понимание всех требований настоящего стандарта;

    - правильность выбора варианта реализации требований настоящего стандарта при наличии альтернативы;

    - понимание альтернативы или специфических требований, определяемых для машины или ее эксплуатации, при отсутствии или отличии от соответствующих требований настоящего стандарта;

    - точность определения таких специфических требований.

    Приведенная на рисунке 1 блок-схема типичной машины должна быть использована в качестве отправной точки при решении данной задачи. Это определяется пунктами и разделами, имеющими отношение к специфическим требованиям к оборудованию.

    Настоящий стандарт является комплексным документом, и таблица F.1 призвана помочь в понимании применения требований настоящего стандарта к специальным машинам и установлении связей с другими стандартами по данной тематике.

    Таблица F.1 - Выбор вариантов применения требований стандарта

    Наименование раздела, пункта или подпункта

    Номер раздела, пункта или подпункта

    I)

    II)

    III)

    IV)

    Область применения

    1

    X

    ИСО 121 00 (все части) ИСО 14121 [28]

    Общие требования

    4

    X

    X

    X

    МЭК 60439

    Электрооборудование, соответствующее требованиям МЭК 60439

    4.2.2

    X

    X

    Устройство отключения питания (изолирующий распределитель)

    5.3

    X

    Цепи, на которые не распространяются общие правила по подключению к источнику питания

    5.3.5

    X

    X

    ИСО 12100 (все части)

    Предотвращение непреднамеренных пусков, изоляция

    5.4, 5.5, 5.6

    X

    X

    X

    ИСО 14118 [13]

    Защита от поражения электрическим током

    6

    X

    МЭК 60364-4-41

    Аварийное управление

    9.2.5.4

    X

    X

    ИСО 13850

    Двуручное управление

    9.2.6.2

    X

    X

    ИСО 13851 [14]

    Дистанционное управление

    9.2.7

    X

    X

    X

    Функции управления в случае отказа

    9.4

    X

    X

    X

    ИСО 14121 [28]

    Датчики положения

    10.1.4

    X

    X

    X

    ИСО 14119 [29]

    Цвета и маркировка операционного интерфейса

    10.2, 10.3, 10.4

    X

    X

    МЭК 60073

    Устройства аварийной остановки

    10.7

    X

    X

    ИСО 13850

    Устройства аварийного отключения

    10.8

    X

    Аппаратура управления, защита от внешних воздействий

    10.1.3, 11.3

    X

    X

    X

    МЭК 60529

    Идентификация проводов

    13.2

    X

    Подтверждение соответствия (испытания и проверка)

    18

    X

    X

    X

    Дополнительные требования (опросный лист)

    приложение В

    X

    X

    «X» обозначены разделы, пункты и подпункты настоящего стандарта, которые могут быть применены при следующих условиях:

    I) применение приведенных в разделе, пункте или подпункте материалов;

    II) использование дополнительных специфических требований;

    III) использование других требований;

    IV) использование других стандартов, в которых требования к электрооборудованию аналогичны настоящему стандарту.

    <2>Приложение G

    Таблица G.1 иллюстрирует сравнение поперечных сечений проводников в Американском сортаменте проволоки (AWG) с квадратными миллиметрами, квадратными дюймами и круговыми милами.

    Таблица G.1 - Сравнение размеров проводников

    Номерной размер,

    Номер диаметра

    Площадь поперечного сечения

    Сопротивление медного провода при постоянном токе при 20°С,

    Круговой мил

    мм2

    дюйм2

    0,2

    0,196

    0,000304

    91,62

    387

    24

    0,205

    0,000317

    87,60

    404

    0,3

    0,283

    0,000438

    63,46

    558

    22

    0,324

    0,000504

    55,44

    640

    0,5

    0,500

    0,000775

    36,70

    987

    20

    0,519

    0,000802

    34,45

    1020

    0,75

    0,750

    0,001162

    24,80

    1480

    18

    0,823

    0,001272

    20,95

    1620

    1,0

    1,000

    0,001550

    18,20

    1973

    16

    1,31

    0,002026

    13,19

    2580

    1,5

    1,500

    0,002325

    12,20

    2960

    14

    2,08

    0,003228

    8,442

    4110

    2,5

    2,500

    0,003875

    7,56

    4934

    12

    3,31

    0,005129

    5,315

    6530

    4

    4,000

    0,006200

    4,700

    7894

    10

    5,26

    0,008152

    3,335

    10380

    6

    6,000

    0,009300

    3,110

    11841

    8

    8,37

    0,012967

    2,093

    16510

    10

    10,000

    0,001550

    1,840

    19735

    6

    13,3

    0,020610

    1,320

    26240

    16

    16,000

    0,024800

    1,160

    31576

    4

    21,1

    0,032780

    0,8295

    41740

    25

    25,000

    0,038800

    0,7340

    49339

    2

    33,6

    0,052100

    0,5211

    66360

    35

    35,000

    0,054200

    0,5290

    69073

    1

    42,4

    0,065700

    0,4139

    83690

    50

    47,000

    0,072800

    0,3910

    92756

    Сопротивление при температурах, отличных от 20 °С, вычисляют по формуле:

    R = RI[1 + 0,00393(t - 20)],

    где RI - сопротивление при 20°С;

    R - сопротивление при температуре t°C.

    <2>Приложение Н

    Таблица Н.1

    Обозначение ссылочного международного стандарта

    Обозначение и наименование соответствующего национального стандарта

    МЭК 60034-1

    ГОСТ 28330-89 Машины электрические асинхронные мощностью от 1 до 400 кВт включительно. Общие технические требования

    МЭК 60034-5

    *

    МЭК 60034-11

    *

    МЭК 60072-1

    *

    МЭК 60072-2

    *

    МЭК 60073:2002

    ГОСТ 29149-91 Цвета световой сигнализации и кнопок

    МЭК 60309-1:1999

    ГОСТ 29146.1-91 Соединители электрические промышленного назначения. Часть 1. Общие требования

    МЭК 60364-4-41:2001

    ГОСТ Р 50571.3-94( МЭК 60364-4-41-92) Электроустановки зданий. Часть 4. Требования по обеспечению безопасности. Защита от поражения электрическим током

    МЭК 60364-4-43:2001

    ГОСТ Р 50571.5-95 (МЭК 60364-4-43-77) Электроустановки зданий. Часть 4. Требования по обеспечению безопасности. Защита от сверхтока

    МЭК 60364-5-52:2001

    ГОСТ Р 50571.15-97( МЭК 60364-5-52-93) Электроустановки зданий. Часть 5. Выбор и монтаж электрооборудования. Глава 52. Электропроводки

    МЭК 60364-5-53:2002

    *

    МЭК 60364-5-54:2002

    ГОСТ Р 50571.10-96( МЭК 60364-5-54-80) Электроустановки зданий. Часть 5. Выбор и монтаж электрооборудования. Глава 54. Заземляющие устройства и защитные проводники

    МЭК 60364-6-61:2001

    ГОСТ Р 50571.16-99 Электроустановки зданий. Часть 6. Испытания. Глава 61. Приемо-сдаточные испытания

    МЭК 604 17-DB 2002

    *

    МЭК 60439-1:1999

    ГОСТ Р 51321.1-2000 Устройства комплектные низковольтные распределения и управления. Часть 1.Устройства, испытанные полностью или частично. Общие технические требования и методы испытаний

    МЭК 60446:1 999

    *

    МЭК 60447:2004

    ГОСТ Р МЭК 60447-2000 Интерфейс человеко-машинный. Принципы приведения в действие

    МЭК 60529:1999

    ГОСТ 14254-96( МЭК 529-89) Степени защиты, обеспечиваемые оболочками (Код IP)

    МЭК 60617-06:2001

    *

    МЭК 60621-3:1979

    *

    МЭК 60664-1:1992

    *

    МЭК 60947-1:2004

    ГОСТ Р 50030.1-2007( МЭК 60947-1: 2004) Аппаратура распределения и управления низковольтная. Часть 1. Общие требования

    МЭК 60947-2:2003

    ГОСТ Р 50030.2-99( МЭК 60947-2-98) Аппаратура распределения и управления низковольтная. Часть 2. Автоматические выключатели

    МЭК 60947-5-1:2003

    ГОСТ Р 50030.5.1-2005 (МЭК 60947-5-1:2003) Аппаратура распределения и управления низковольтная. Часть 5. Аппараты и коммутационные элементы цепей управления. Глава 1. Электромеханические аппараты для цепей управления

    МЭК 60947-7-1:2002

    ГОСТ Р 50030.7.1-2000 (МЭК 60947-7-1-89) Аппаратура распределения и управления низковольтная. Часть 7. Электрооборудование вспомогательное. Раздел 1. Клеммные колодки для медных проводников

    МЭК 61082-1:1991

    *

    МЭК 61082-2:1993

    *

    МЭК 61082-3:1993

    *

    МЭК 61082-4:1996

    *

    МЭК 61140:2001

    ГОСТ Р МЭК 61140-2000 Защита от поражения электрическим током. Общие положения по безопасности, обеспечиваемой электрооборудованием и электроустановками в их взаимосвязи

    МЭК 61310 -2

    ГОСТ 28690-90 Знак соответствия технических средств требованиям электромагнитной совместимости. Форма, размеры, технические требования

    МЭК 61 310 (все части за исключением части 2)

    *

    МЭК 61 346 (все части)

    *

    МЭК 61557-3:1997

    ГОСТ Р МЭК 61557-3 2006 Сети электрические распределительные низковольтные напряжением до 1000 В переменного 1500 В постоянного тока. Электробезопасность. Аппаратура для испытаний, измерения и контроля средств защиты. Часть 3. Полное сопротивление контура

    МЭК 61 558-1: 1997

    *

    МЭК 61558-2-6

    *

    МЭК 61984:2001

    *

    МЭК 62023:2000

    *

    МЭК 62027:2000

    *

    МЭК 62061:2005

    *

    МЭК 62079:2001

    *

    ИСО 7000:2004

    *

    ИСО 12100-1:2003

    *

    ИСО 12100-2:2003

    *

    ИСО 13849-1:1999

    *

    ИСО 13849-2:2003

    *

    ИСО 13850:1996

    *

    *Соответствующий национальный стандарт отсутствует. До его утверждения рекомендуется использовать перевод на русский язык данного международного стандарта. Перевод данного международного стандарта находится в Федеральном информационном фонде технических регламентов и стандартов

    <2>Библиография

    [1] МЭК 60038:2002

    Стандартные напряжения

    [2] МЭК 60204-11:2000

    Безопасность машин. Электрическое оборудование машин. Часть 11. Требования к высоковольтному оборудованию на напряжения свыше 1000 В переменного тока или 1500 В постоянного тока, но не свыше 36 кВ

    [3] МЭК 60204-31:1996

    Электрооборудование промышленных машин. Частные требования к швейным машинам, установкам и системам

    [4] МЭК 60204-32:1998

    Безопасность оборудования. Электрооборудование промышленных  машин. Часть 32. Требования к грузоподъемным машинам

    [5] МЭК 61000-6-1:1997

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 1. Устойчивость к электромагнитным помехам в жилой, коммерческой и среде легкой индустрии

    [6] МЭК 61000-6-2:2005

    Совместимость технических средств электромагнитная. Часть 6-2. Общие требования. Устойчивость к электромагнитным помехам в промышленных зонах

    [7] СИСПР 61000-6-3:1996

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 3. Нормы эмиссии для жилых, коммерческих и среды легкой индустрии

    [8] МЭК 61000-6-4:1997

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 4. Эмиссия помех в промышленных зонах

    [9] МЭК 61000-5-2:1997

    Электромагнитная совместимость. Часть 5. Монтаж и снижение помех в проводке. Раздел 2. Заземление и скрутка

    [10] МЭК 61496-1:2004

    Безопасность машин. Электрочувствительное защитное оборудование. Часть 1. Общие требования и испытания

    [11] МЭК 61800-3:2004

    Электроприводы регулируемые. Часть 3. Требования по электромагнитной совместимости и методы испытаний

    [12] МЭК 60947-5-2:1997

    Аппараты коммутационные и управления низковольтные. Часть 5-2. Устройства управления и переключатели. Выключатели конечные Дополнение 1 (1999) Дополнение 2 (2003)

    [13] ИСО 14118:2000

    Безопасность машин. Предотвращение непредусмотренного пуска

    [14] ИСО 13851:2002

    Безопасность машин. Средства управления обоими руками. Функциональные аспекты и принципы проектирования

    [15] ИСО 14122 серия

    Безопасность машин. Средства постоянного доступа к машине

    [16]СЕНЕЛЕК НD 516 S2

    Руководство по применению гармонизированных кабелей

    [17] МЭК 60287 (все части)

    Кабели. Расчет номинальных токов нагрузок в условиях установившегося режима

    [18] МЭК 60757:1983

    Коды для обозначения цветов

    [19] МЭК 60332 (все части)

    Испытания на огнестойкость электрических и оптических кабелей

    [20] МЭК 61084-1: 1991

    Кабельные проводящие и канализирующие системы для электрического монтажа. Часть 1. Основные требования

    [21] МЭК 60364 (все части)

    Электроустановки зданий

    [22] МЭК 61557 (все части)

    Безопасность в низковольтных  системах  электроснабжения   напряжением до 1000 В переменного тока и до 1500 В постоянного тока. Оборудование для проведения испытаний, измерений и контроля исполнения защитных функций

    [23] МЭК 60228:2004

    Жилы токопроводящие изолированных кабелей

    [24] МЭК 61200-53:1994

    Устройства электрические. Часть 53. Выбор и монтаж электрооборудования. Аппаратура коммутационная и управления

    [25] МЭК 61180-2:1994

    Техника для проведения высоковольтных испытаний низковольтного электрооборудования. Часть 2. Испытательное оборудование

    [26] МЭК 60335 (все части)

    Бытовое и аналогичное ему применение электричества. Безопасность

    [27] МЭК 60269-1:1998

    Предохранители низковольтные. Часть 1. Общие требования

    [28] ИСО 14121:1999

    Безопасность машин. Принципы оценки риска

    [29] ИСО 14119:1998

    Безопасность машин. Блокировочные устройства для ограждений. Принципы конструкции и выбора

    <2>

    Источник: ГОСТ Р МЭК 60204-1-2007: Безопасность машин. Электрооборудование машин и механизмов. Часть 1. Общие требования оригинал документа

    Англо-русский словарь нормативно-технической терминологии > III)

  • 4 IV)

    1. Общее

    F.1. Общее

    В настоящем стандарте приводится большое число общих требований, которые могут или не могут быть применены в отношении отдельной машины. Поэтому простое, без квалифицированной оценки утверждение о соответствии оборудования всем требованиям настоящего стандарта является недостоверным. Прежде чем приступить к выполнению требований настоящего стандарта, его необходимо тщательно изучить. Техническими комитетами разрабатываются стандарты на отдельные виды продукции или на отдельные продукты (тип С в СЕН) и для конкретных производителей продукции. До выхода этих стандартов следует руководствоваться настоящим стандартом посредством:

    a) установления соответствия и

    b) выбора наиболее близких понятий к требованиям соответствующих разделов, и

    c) изменения требований разделов, если необходимо там, где специфические требования на машину перекрываются другими стандартами, относящимися к данному вопросу.

    В этом случае необходимо обеспечить правильный подбор модификаций и опций без снижения уровня защиты, необходимой для машины в соответствии с оценкой рисков.

    При использовании всех трех вышеприведенных принципов рекомендуется:

    - руководствоваться соответствующими разделами и пунктами настоящего стандарта:

    1) если указано соответствие применяемой опции,

    2) если требования могут быть конкретизированы для отдельной машины или оборудования;

    - руководствоваться напрямую соответствующими стандартами, в которых требования к электрооборудованию аналогичны настоящему стандарту.

    Во всех случаях экспертизой устанавливается:

    - завершенность оценки рисков для машины;

    - прочтение и понимание всех требований настоящего стандарта;

    - правильность выбора варианта реализации требований настоящего стандарта при наличии альтернативы;

    - понимание альтернативы или специфических требований, определяемых для машины или ее эксплуатации, при отсутствии или отличии от соответствующих требований настоящего стандарта;

    - точность определения таких специфических требований.

    Приведенная на рисунке 1 блок-схема типичной машины должна быть использована в качестве отправной точки при решении данной задачи. Это определяется пунктами и разделами, имеющими отношение к специфическим требованиям к оборудованию.

    Настоящий стандарт является комплексным документом, и таблица F.1 призвана помочь в понимании применения требований настоящего стандарта к специальным машинам и установлении связей с другими стандартами по данной тематике.

    Таблица F.1 - Выбор вариантов применения требований стандарта

    Наименование раздела, пункта или подпункта

    Номер раздела, пункта или подпункта

    I)

    II)

    III)

    IV)

    Область применения

    1

    X

    ИСО 121 00 (все части) ИСО 14121 [28]

    Общие требования

    4

    X

    X

    X

    МЭК 60439

    Электрооборудование, соответствующее требованиям МЭК 60439

    4.2.2

    X

    X

    Устройство отключения питания (изолирующий распределитель)

    5.3

    X

    Цепи, на которые не распространяются общие правила по подключению к источнику питания

    5.3.5

    X

    X

    ИСО 12100 (все части)

    Предотвращение непреднамеренных пусков, изоляция

    5.4, 5.5, 5.6

    X

    X

    X

    ИСО 14118 [13]

    Защита от поражения электрическим током

    6

    X

    МЭК 60364-4-41

    Аварийное управление

    9.2.5.4

    X

    X

    ИСО 13850

    Двуручное управление

    9.2.6.2

    X

    X

    ИСО 13851 [14]

    Дистанционное управление

    9.2.7

    X

    X

    X

    Функции управления в случае отказа

    9.4

    X

    X

    X

    ИСО 14121 [28]

    Датчики положения

    10.1.4

    X

    X

    X

    ИСО 14119 [29]

    Цвета и маркировка операционного интерфейса

    10.2, 10.3, 10.4

    X

    X

    МЭК 60073

    Устройства аварийной остановки

    10.7

    X

    X

    ИСО 13850

    Устройства аварийного отключения

    10.8

    X

    Аппаратура управления, защита от внешних воздействий

    10.1.3, 11.3

    X

    X

    X

    МЭК 60529

    Идентификация проводов

    13.2

    X

    Подтверждение соответствия (испытания и проверка)

    18

    X

    X

    X

    Дополнительные требования (опросный лист)

    приложение В

    X

    X

    «X» обозначены разделы, пункты и подпункты настоящего стандарта, которые могут быть применены при следующих условиях:

    I) применение приведенных в разделе, пункте или подпункте материалов;

    II) использование дополнительных специфических требований;

    III) использование других требований;

    IV) использование других стандартов, в которых требования к электрооборудованию аналогичны настоящему стандарту.

    <2>Приложение G

    Таблица G.1 иллюстрирует сравнение поперечных сечений проводников в Американском сортаменте проволоки (AWG) с квадратными миллиметрами, квадратными дюймами и круговыми милами.

    Таблица G.1 - Сравнение размеров проводников

    Номерной размер,

    Номер диаметра

    Площадь поперечного сечения

    Сопротивление медного провода при постоянном токе при 20°С,

    Круговой мил

    мм2

    дюйм2

    0,2

    0,196

    0,000304

    91,62

    387

    24

    0,205

    0,000317

    87,60

    404

    0,3

    0,283

    0,000438

    63,46

    558

    22

    0,324

    0,000504

    55,44

    640

    0,5

    0,500

    0,000775

    36,70

    987

    20

    0,519

    0,000802

    34,45

    1020

    0,75

    0,750

    0,001162

    24,80

    1480

    18

    0,823

    0,001272

    20,95

    1620

    1,0

    1,000

    0,001550

    18,20

    1973

    16

    1,31

    0,002026

    13,19

    2580

    1,5

    1,500

    0,002325

    12,20

    2960

    14

    2,08

    0,003228

    8,442

    4110

    2,5

    2,500

    0,003875

    7,56

    4934

    12

    3,31

    0,005129

    5,315

    6530

    4

    4,000

    0,006200

    4,700

    7894

    10

    5,26

    0,008152

    3,335

    10380

    6

    6,000

    0,009300

    3,110

    11841

    8

    8,37

    0,012967

    2,093

    16510

    10

    10,000

    0,001550

    1,840

    19735

    6

    13,3

    0,020610

    1,320

    26240

    16

    16,000

    0,024800

    1,160

    31576

    4

    21,1

    0,032780

    0,8295

    41740

    25

    25,000

    0,038800

    0,7340

    49339

    2

    33,6

    0,052100

    0,5211

    66360

    35

    35,000

    0,054200

    0,5290

    69073

    1

    42,4

    0,065700

    0,4139

    83690

    50

    47,000

    0,072800

    0,3910

    92756

    Сопротивление при температурах, отличных от 20 °С, вычисляют по формуле:

    R = RI[1 + 0,00393(t - 20)],

    где RI - сопротивление при 20°С;

    R - сопротивление при температуре t°C.

    <2>Приложение Н

    Таблица Н.1

    Обозначение ссылочного международного стандарта

    Обозначение и наименование соответствующего национального стандарта

    МЭК 60034-1

    ГОСТ 28330-89 Машины электрические асинхронные мощностью от 1 до 400 кВт включительно. Общие технические требования

    МЭК 60034-5

    *

    МЭК 60034-11

    *

    МЭК 60072-1

    *

    МЭК 60072-2

    *

    МЭК 60073:2002

    ГОСТ 29149-91 Цвета световой сигнализации и кнопок

    МЭК 60309-1:1999

    ГОСТ 29146.1-91 Соединители электрические промышленного назначения. Часть 1. Общие требования

    МЭК 60364-4-41:2001

    ГОСТ Р 50571.3-94( МЭК 60364-4-41-92) Электроустановки зданий. Часть 4. Требования по обеспечению безопасности. Защита от поражения электрическим током

    МЭК 60364-4-43:2001

    ГОСТ Р 50571.5-95 (МЭК 60364-4-43-77) Электроустановки зданий. Часть 4. Требования по обеспечению безопасности. Защита от сверхтока

    МЭК 60364-5-52:2001

    ГОСТ Р 50571.15-97( МЭК 60364-5-52-93) Электроустановки зданий. Часть 5. Выбор и монтаж электрооборудования. Глава 52. Электропроводки

    МЭК 60364-5-53:2002

    *

    МЭК 60364-5-54:2002

    ГОСТ Р 50571.10-96( МЭК 60364-5-54-80) Электроустановки зданий. Часть 5. Выбор и монтаж электрооборудования. Глава 54. Заземляющие устройства и защитные проводники

    МЭК 60364-6-61:2001

    ГОСТ Р 50571.16-99 Электроустановки зданий. Часть 6. Испытания. Глава 61. Приемо-сдаточные испытания

    МЭК 604 17-DB 2002

    *

    МЭК 60439-1:1999

    ГОСТ Р 51321.1-2000 Устройства комплектные низковольтные распределения и управления. Часть 1.Устройства, испытанные полностью или частично. Общие технические требования и методы испытаний

    МЭК 60446:1 999

    *

    МЭК 60447:2004

    ГОСТ Р МЭК 60447-2000 Интерфейс человеко-машинный. Принципы приведения в действие

    МЭК 60529:1999

    ГОСТ 14254-96( МЭК 529-89) Степени защиты, обеспечиваемые оболочками (Код IP)

    МЭК 60617-06:2001

    *

    МЭК 60621-3:1979

    *

    МЭК 60664-1:1992

    *

    МЭК 60947-1:2004

    ГОСТ Р 50030.1-2007( МЭК 60947-1: 2004) Аппаратура распределения и управления низковольтная. Часть 1. Общие требования

    МЭК 60947-2:2003

    ГОСТ Р 50030.2-99( МЭК 60947-2-98) Аппаратура распределения и управления низковольтная. Часть 2. Автоматические выключатели

    МЭК 60947-5-1:2003

    ГОСТ Р 50030.5.1-2005 (МЭК 60947-5-1:2003) Аппаратура распределения и управления низковольтная. Часть 5. Аппараты и коммутационные элементы цепей управления. Глава 1. Электромеханические аппараты для цепей управления

    МЭК 60947-7-1:2002

    ГОСТ Р 50030.7.1-2000 (МЭК 60947-7-1-89) Аппаратура распределения и управления низковольтная. Часть 7. Электрооборудование вспомогательное. Раздел 1. Клеммные колодки для медных проводников

    МЭК 61082-1:1991

    *

    МЭК 61082-2:1993

    *

    МЭК 61082-3:1993

    *

    МЭК 61082-4:1996

    *

    МЭК 61140:2001

    ГОСТ Р МЭК 61140-2000 Защита от поражения электрическим током. Общие положения по безопасности, обеспечиваемой электрооборудованием и электроустановками в их взаимосвязи

    МЭК 61310 -2

    ГОСТ 28690-90 Знак соответствия технических средств требованиям электромагнитной совместимости. Форма, размеры, технические требования

    МЭК 61 310 (все части за исключением части 2)

    *

    МЭК 61 346 (все части)

    *

    МЭК 61557-3:1997

    ГОСТ Р МЭК 61557-3 2006 Сети электрические распределительные низковольтные напряжением до 1000 В переменного 1500 В постоянного тока. Электробезопасность. Аппаратура для испытаний, измерения и контроля средств защиты. Часть 3. Полное сопротивление контура

    МЭК 61 558-1: 1997

    *

    МЭК 61558-2-6

    *

    МЭК 61984:2001

    *

    МЭК 62023:2000

    *

    МЭК 62027:2000

    *

    МЭК 62061:2005

    *

    МЭК 62079:2001

    *

    ИСО 7000:2004

    *

    ИСО 12100-1:2003

    *

    ИСО 12100-2:2003

    *

    ИСО 13849-1:1999

    *

    ИСО 13849-2:2003

    *

    ИСО 13850:1996

    *

    *Соответствующий национальный стандарт отсутствует. До его утверждения рекомендуется использовать перевод на русский язык данного международного стандарта. Перевод данного международного стандарта находится в Федеральном информационном фонде технических регламентов и стандартов

    <2>Библиография

    [1] МЭК 60038:2002

    Стандартные напряжения

    [2] МЭК 60204-11:2000

    Безопасность машин. Электрическое оборудование машин. Часть 11. Требования к высоковольтному оборудованию на напряжения свыше 1000 В переменного тока или 1500 В постоянного тока, но не свыше 36 кВ

    [3] МЭК 60204-31:1996

    Электрооборудование промышленных машин. Частные требования к швейным машинам, установкам и системам

    [4] МЭК 60204-32:1998

    Безопасность оборудования. Электрооборудование промышленных  машин. Часть 32. Требования к грузоподъемным машинам

    [5] МЭК 61000-6-1:1997

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 1. Устойчивость к электромагнитным помехам в жилой, коммерческой и среде легкой индустрии

    [6] МЭК 61000-6-2:2005

    Совместимость технических средств электромагнитная. Часть 6-2. Общие требования. Устойчивость к электромагнитным помехам в промышленных зонах

    [7] СИСПР 61000-6-3:1996

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 3. Нормы эмиссии для жилых, коммерческих и среды легкой индустрии

    [8] МЭК 61000-6-4:1997

    Совместимость технических средств электромагнитная. Часть 6. Общие требования. Секция 4. Эмиссия помех в промышленных зонах

    [9] МЭК 61000-5-2:1997

    Электромагнитная совместимость. Часть 5. Монтаж и снижение помех в проводке. Раздел 2. Заземление и скрутка

    [10] МЭК 61496-1:2004

    Безопасность машин. Электрочувствительное защитное оборудование. Часть 1. Общие требования и испытания

    [11] МЭК 61800-3:2004

    Электроприводы регулируемые. Часть 3. Требования по электромагнитной совместимости и методы испытаний

    [12] МЭК 60947-5-2:1997

    Аппараты коммутационные и управления низковольтные. Часть 5-2. Устройства управления и переключатели. Выключатели конечные Дополнение 1 (1999) Дополнение 2 (2003)

    [13] ИСО 14118:2000

    Безопасность машин. Предотвращение непредусмотренного пуска

    [14] ИСО 13851:2002

    Безопасность машин. Средства управления обоими руками. Функциональные аспекты и принципы проектирования

    [15] ИСО 14122 серия

    Безопасность машин. Средства постоянного доступа к машине

    [16]СЕНЕЛЕК НD 516 S2

    Руководство по применению гармонизированных кабелей

    [17] МЭК 60287 (все части)

    Кабели. Расчет номинальных токов нагрузок в условиях установившегося режима

    [18] МЭК 60757:1983

    Коды для обозначения цветов

    [19] МЭК 60332 (все части)

    Испытания на огнестойкость электрических и оптических кабелей

    [20] МЭК 61084-1: 1991

    Кабельные проводящие и канализирующие системы для электрического монтажа. Часть 1. Основные требования

    [21] МЭК 60364 (все части)

    Электроустановки зданий

    [22] МЭК 61557 (все части)

    Безопасность в низковольтных  системах  электроснабжения   напряжением до 1000 В переменного тока и до 1500 В постоянного тока. Оборудование для проведения испытаний, измерений и контроля исполнения защитных функций

    [23] МЭК 60228:2004

    Жилы токопроводящие изолированных кабелей

    [24] МЭК 61200-53:1994

    Устройства электрические. Часть 53. Выбор и монтаж электрооборудования. Аппаратура коммутационная и управления

    [25] МЭК 61180-2:1994

    Техника для проведения высоковольтных испытаний низковольтного электрооборудования. Часть 2. Испытательное оборудование

    [26] МЭК 60335 (все части)

    Бытовое и аналогичное ему применение электричества. Безопасность

    [27] МЭК 60269-1:1998

    Предохранители низковольтные. Часть 1. Общие требования

    [28] ИСО 14121:1999

    Безопасность машин. Принципы оценки риска

    [29] ИСО 14119:1998

    Безопасность машин. Блокировочные устройства для ограждений. Принципы конструкции и выбора

    <2>

    Источник: ГОСТ Р МЭК 60204-1-2007: Безопасность машин. Электрооборудование машин и механизмов. Часть 1. Общие требования оригинал документа

    Англо-русский словарь нормативно-технической терминологии > IV)

  • 5 rated voltage

    1. регламентированное напряжение
    2. расчетное напряжение
    3. нормируемое напряжение
    4. номинальное напряжение конденсатора
    5. номинальное напряжение (во взрывозащите)
    6. номинальное напряжение

     

    номинальное напряжение
    Напряжение, установленное изготовителем для прибора
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    номинальное напряжение Uном, кВ
    Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
    [ ГОСТ Р 52726-2007]

    номинальное напряжение

    Un
    Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    rated voltage
    voltage assigned to the appliance by the manufacturer
    [IEC 60335-1, ed. 4.0 (2001-05)]

    rated voltage
    quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    rated voltage
    input or output supply voltage for which equipment is designed or specified
    [IEC 88528-11, ed. 1.0 (2004-03)]

    rated voltage
    specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
    NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    rated voltage
    the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
    NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    rated voltage
    reference voltage for which the cable is designed, and which serves to define the electrical tests
    NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
    Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
    U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
    In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
    This condition applies both to the value Uo and to the value U.
    In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
    NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
    [IEC 60245-1, ed. 4.0 (2003-12)]

    rated voltage
    highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
    [IEC 60800, ed. 3.0 (2009-07)]

    rated voltage
    the r.m.s. line-to-line voltage under rated conditions
    Primary side of input transformer: ULN
    Converter input: UVN
    Converter output: UaN
    Motor voltage: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    rated voltage
    input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
    [IEC 62040-1, ed. 1.0 (2008-06)]

    nominal voltage, Un
    voltage by which a system is designated or identified
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    tension assignée
    tension attribuée à l'appareil par le fabricant
    [IEC 60335-1, ed. 4.0 (2001-05)]

    tension nominale
    tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    tension assignée
    tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
    NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    tension assignée
    valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
    NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    tension assignée
    tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
    NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
    Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
    U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
    Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
    Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
    Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
    NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
    [IEC 60245-1, ed. 4.0 (2003-12)]

    tension assignée
    tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
    [IEC 60800, ed. 3.0 (2009-07)]

    tension assignée
    valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
    Primaire du transformateur d’entrée: ULN
    Entrée du convertisseur: UVN
    Sortie du convertisseur: UaN
    Moteur: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    tension assignée
    tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
    [IEC 62040-1, ed. 1.0 (2008-06)]

    tension nominale, Un
    tension par laquelle un réseau est désigné ou identifié
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    Синонимы

    • Un

    EN

    FR

     

    номинальное напряжение
    Значение напряжения, на которое рассчитаны рабочие и эксплуатационные характеристики распределенных электронагревателей.
    [ ГОСТ Р МЭК 60050-426-2006]


    Тематики

    EN

     

    номинальное напряжение конденсатора
    Максимальное напряжение, при котором конденсатор может работать в течение минимальной наработки в условиях, указанных в нормативно-технической документации
    [ ГОСТ 21415-75]

    номинальное напряжение конденсатора
    Действующее значение синусоидального переменного напряжения при номинальной частоте, на которое рассчитан конденсатор. Номинальное напряжение многофазного конденсатора - значение напряжения между выводами.
    [ ГОСТ 1282-88]

    Тематики

    EN

    DE

    FR

     

    нормируемое напряжение
    Питающее напряжение или напряжение, на которое светильник рассчитан изготовителем.
    [ ГОСТ Р МЭК 60598-1-2014]

    Тематики

    • лампы, светильники, приборы и комплексы световые

    EN

     

    расчетное напряжение
    номинальное напряжение
    нормальное эксплуатационное напряжение


    [Л.Г.Суменко. Англо-русский словарь по информационным технологиям. М.: ГП ЦНИИС, 2003.]

    Тематики

    Синонимы

    EN

     

    расчётное напряжение

    [Я.Н.Лугинский, М.С.Фези-Жилинская, Ю.С.Кабиров. Англо-русский словарь по электротехнике и электроэнергетике, Москва, 1999]

    Тематики

    • электротехника, основные понятия

    EN

    1.5.10 номинальное напряжение (rated voltage): Номинальное напряжение - это либо эффективное значение рабочего напряжения номинальной частоты, либо рабочее постоянное напряжение, которое можно длительно подавать на выводы конденсатора при любой температуре между нижней и верхней температурами категории. Это означает, что у конденсаторов, на которые распространяется настоящий стандарт, напряжение категории равно номинальному напряжению.

    Источник: ГОСТ Р МЭК 60384-14-2004: Конденсаторы постоянной емкости для электронной аппаратуры. Часть 14. Групповые технические условия на конденсаторы постоянной емкости для подавления электромагнитных помех и соединения с питающими магистралями оригинал документа

    3.2.1 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем для этой машины, или напряжение между фазами (линейное) - при трехфазном питании.

    Источник: ГОСТ Р МЭК 60745-1-2005: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа

    3.25 номинальное напряжение (rated voltage): Напряжение, установленное изготовителем соединителей, которое указывается в стандартах или технических условиях.

    Источник: ГОСТ Р 51322.1-2011: Соединители электрические штепсельные бытового и аналогичного назначения. Часть 1. Общие требования и методы испытаний оригинал документа

    3.23 номинальное напряжение (rated voltage): Значение напряжения, на которое рассчитаны рабочие и эксплуатационные характеристики распределенных электронагревателей.

    Источник: ГОСТ Р МЭК 60079-30-1-2009: Взрывоопасные среды. Резистивный распределенный электронагреватель. Часть 30-1. Общие технические требования и методы испытаний оригинал документа

    1.5.9 номинальное напряжение (rated voltage): Напряжение или диапазон напряжения, заданное(ый) в соответствии с настоящим стандартом.

    Примечание - Если в маркировке на лампе приведен диапазон напряжения, это значит, что возможна эксплуатация ламп при любом значении напряжения в пределах этого диапазона.

    Источник: ГОСТ Р 52706-2007: Лампы накаливания вольфрамовые для бытового и аналогичного общего освещения. Эксплуатационные требования оригинал документа

    2.1 нормируемое напряжение (rated voltage): Максимальное рабочее напряжение, заявленное изготовителем, на которое рассчитан патрон.

    Источник: ГОСТ Р МЭК 60838-1-2008: Патроны различные для ламп. Часть 1. Общие требования и методы испытаний оригинал документа

    1.2.1.1. номинальное напряжение (rated voltage): Указанное изготовителем напряжение источника сетевого электропитания (для трехфазного источника электропитания принимают линейное напряжение).

    Источник: ГОСТ Р МЭК 60950-1-2009: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа

    1.2.1.1 номинальное напряжение (rated voltage): Указанное изготовителем напряжение источника сетевого электропитания (для трехфазного источника электропитания принимают линейное напряжение).

    Источник: ГОСТ Р МЭК 60950-1-2005: Оборудование информационных технологий. Требования безопасности. Часть 1. Общие требования оригинал документа

    3.37 номинальное напряжение (rated voltage): Значение напряжения для заданных условий эксплуатации.

    Значение и условия должны быть указаны в соответствующем стандарте или изготовителем, или ответственным поставщиком.

    Примечание - Номинальное напряжение выражают в вольтах (В).

    Источник: ГОСТ Р 54814-2011: Светодиоды и светодиодные модули для общего освещения. Термины и определения оригинал документа

    1.3.4 номинальное напряжение (rated voltage): Напряжение или диапазон напряжения, заданное(ый) в соответствии с настоящим стандартом.

    Примечание - Если в маркировке на лампе приведен диапазон напряжения, это значит, что возможна эксплуатация ламп при любом значении напряжения в пределах этого диапазона.

    Источник: ГОСТ Р 52712-2007: Требования безопасности для ламп накаливания. Часть 1. Лампы накаливания вольфрамовые для бытового и аналогичного общего освещения оригинал документа

    3.40 номинальное напряжение (rated voltage): Напряжение, установленное для машины изготовителем. При трехфазном питании - напряжение между фазами.

    Источник: ГОСТ Р МЭК 60745-1-2009: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования оригинал документа

    3.2.1 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем для этой машины, или напряжение между фазами (линейное) - при трехфазном питании.

    Источник: ГОСТ IEC 60745-1-2011: Машины ручные электрические. Безопасность и методы испытаний. Часть 1. Общие требования

    3.11 номинальное напряжение (rated voltage), UH (UN): Напряжение при номинальной частоте, прикладываемое между линейными выводами обмотки.

    Источник: ГОСТ Р 54801-2011: Трансформаторы тяговые и реакторы железнодорожного подвижного состава. Основные параметры и методы испытаний оригинал документа

    3.103 номинальное напряжение (rated voltage): Напряжение, указанное изготовителем, для конкретного корпуса.

    Источник: ГОСТ Р 50827.5-2009: Коробки и корпусы для электрических аппаратов, устанавливаемые в стационарные электрические установки бытового и аналогичного назначения. Часть 24. Специальные требования к коробкам и корпусам, предназначенным для установки защитных и аналогичных аппаратов с большой рассеиваемой мощностью оригинал документа

    3.2.1 номинальное напряжение (rated voltage); Ur:Междуфазное напряжение на выводах генератора при номинальных частоте и мощности.

    Примечание - Номинальное напряжение генератора для рабочих и эксплуатационных характеристик устанавливает изготовитель.

    Источник: ГОСТ Р 53986-2010: Электроагрегаты генераторные переменного тока с приводом от двигателя внутреннего сгорания. Часть 3. Генераторы переменного тока оригинал документа

    3.2.1. номинальное напряжение (rated voltage):

    Напряжение, для которого сконструирована установка (или ее часть).

    Источник: ГОСТ Р МЭК 60519-1-2005: Безопасность электротермического оборудования. Часть 1. Общие требования оригинал документа

    2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель и которое служит для определения параметров электрических испытаний.

    Источник: ГОСТ Р МЭК 60245-1-2006: Кабели с резиновой изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа

    2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель и которое служит для определения параметров электрических испытаний.

    Примечание 1 - Номинальное напряжение выражается сочетанием двух значений U0/U, выраженных в вольтах (В):

    U0 - среднеквадратическое значение между любой изолированной жилой и «землей» (металлическим покрытием кабеля или окружающей средой);

    U - среднеквадратическое значение между любыми двумя фазными жилами многожильного кабеля или системы одножильных кабелей.

    В системе переменного тока номинальное напряжение кабеля должно быть не менее номинального напряжения системы, для которой он предназначен.

    Это условие относится как к значению U0, так и к значению U.

    В системе постоянного тока номинальное напряжение системы должно быть не более полуторного значения номинального напряжения кабеля.

    Примечание 2 - Рабочее напряжение системы может постоянно превышать номинальное напряжение такой системы до 10 %. Кабель можно использовать при рабочем напряжении на 10 % выше его номинального напряжения, если последнее по крайней мере равно номинальному напряжению системы.

    Источник: ГОСТ Р МЭК 60245-1-2009: Кабели с резиновой изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа

    1.2.11 нормируемое напряжение (rated voltage): Питающее напряжение или напряжение, на которое светильник рассчитан изготовителем.

    Источник: ГОСТ Р МЭК 60598-1-2011: Светильники. Часть 1. Общие требования и методы испытаний оригинал документа

    2.3 номинальное напряжение (rated voltage): Стандартное напряжение, на которое рассчитан кабель, служащее для определения параметров электрических испытаний.

    Номинальное напряжение выражают сочетанием двух значений - U0/U, выраженных в вольтах:

    U0- среднеквадратическое значение между любой изолированной жилой и «землей» (металлическим покрытием кабеля или окружающей средой);

    U - среднеквадратическое значение между любыми двумя фазными жилами многожильного кабеля или системы одножильных кабелей.

    В системе переменного тока номинальное напряжение кабеля должно быть не менее номинального напряжения системы, для которого он предназначен.

    Это требование относится как к значению U0, так и к значению U.

    В системе постоянного тока номинальное напряжение системы должно быть не более полуторного значения номинального напряжения кабеля.

    Примечание - Рабочее напряжение системы может постоянно превышать номинальное напряжение этой системы до 10 %. Кабель можно использовать при рабочем напряжении, на 10 % превышающем номинальное напряжение, если последнее по крайней мере равно номинальному напряжению системы.

    Источник: ГОСТ Р МЭК 60227-1-2009: Кабели с поливинилхлоридной изоляцией на номинальное напряжение до 450/750 В включительно. Часть 1. Общие требования оригинал документа

    3.2.4 регламентированное напряжение (rated voltage): Входное или выходное напряжение (напряжение фаза - фаза для трехфазного источника питания), указанное производителем.

    Источник: ГОСТ Р 55061-2012: Совместимость технических средств электромагнитная. Статические системы переключения. Часть 2. Требования и методы испытаний оригинал документа

    Англо-русский словарь нормативно-технической терминологии > rated voltage

  • 6 nominal voltage

    1. номинальное напряжение химического источника тока
    2. номинальное напряжение пьезоэлектрического (электромеханического) фильтра
    3. номинальное напряжение аккумулятора
    4. номинальное напряжение
    5. напряжение номинальное

     

    номинальное напряжение
    Напряжение, установленное изготовителем для прибора
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    номинальное напряжение Uном, кВ
    Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
    [ ГОСТ Р 52726-2007]

    номинальное напряжение

    Un
    Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    rated voltage
    voltage assigned to the appliance by the manufacturer
    [IEC 60335-1, ed. 4.0 (2001-05)]

    rated voltage
    quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    rated voltage
    input or output supply voltage for which equipment is designed or specified
    [IEC 88528-11, ed. 1.0 (2004-03)]

    rated voltage
    specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
    NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    rated voltage
    the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
    NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    rated voltage
    reference voltage for which the cable is designed, and which serves to define the electrical tests
    NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
    Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
    U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
    In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
    This condition applies both to the value Uo and to the value U.
    In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
    NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
    [IEC 60245-1, ed. 4.0 (2003-12)]

    rated voltage
    highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
    [IEC 60800, ed. 3.0 (2009-07)]

    rated voltage
    the r.m.s. line-to-line voltage under rated conditions
    Primary side of input transformer: ULN
    Converter input: UVN
    Converter output: UaN
    Motor voltage: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    rated voltage
    input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
    [IEC 62040-1, ed. 1.0 (2008-06)]

    nominal voltage, Un
    voltage by which a system is designated or identified
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    tension assignée
    tension attribuée à l'appareil par le fabricant
    [IEC 60335-1, ed. 4.0 (2001-05)]

    tension nominale
    tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    tension assignée
    tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
    NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    tension assignée
    valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
    NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    tension assignée
    tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
    NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
    Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
    U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
    Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
    Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
    Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
    NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
    [IEC 60245-1, ed. 4.0 (2003-12)]

    tension assignée
    tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
    [IEC 60800, ed. 3.0 (2009-07)]

    tension assignée
    valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
    Primaire du transformateur d’entrée: ULN
    Entrée du convertisseur: UVN
    Sortie du convertisseur: UaN
    Moteur: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    tension assignée
    tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
    [IEC 62040-1, ed. 1.0 (2008-06)]

    tension nominale, Un
    tension par laquelle un réseau est désigné ou identifié
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    Синонимы

    • Un

    EN

    FR

     

    номинальное напряжение пьезоэлектрического (электромеханического) фильтра (Uном, Unom)
    Значение входного напряжения, при котором измеряют параметры пьезоэлектрического (электромеханического) фильтра.
    [ ГОСТ 18670-84]

    Тематики

    EN

    FR

     

    номинальное напряжение химического источника тока
    номинальное напряжение

    Условное напряжение, определяемое электрохимической системой химического источника тока.
    [ ГОСТ 15596-82]

    EN

    nominal voltage
    suitable approximate value of the voltage used to designate or identify a cell, a battery or an electrochemical system
    [IEV number 482-03-31]

    FR

    tension nominale, f
    valeur approchée appropriée d’une tension, utilisée pour désigner ou identifier un élément, une batterie, ou un système électrochimique
    [IEV number 482-03-31]

    Тематики

    Классификация

    >>>

    Синонимы

    EN

    DE

    FR

    • tension nominale, f

    3.4 номинальное напряжение (nominal voltage): Подходящее приблизительное значение напряжения, используемое для идентификации напряжения аккумулятора или батареи.

    Примечания

    1. Номинальное напряжение литиевых аккумуляторов указано в таблице 1.

    2. Номинальное напряжение батареи, состоящей из n соединенных последовательно аккумуляторов, равно номинальному напряжению отдельного аккумулятора, увеличенному в n раз.

    Источник: ГОСТ Р МЭК 61960-2007: Аккумуляторы и аккумуляторные батареи, содержащие щелочной и другие некислотные электролиты. Аккумуляторы и аккумуляторные батареи литиевые для портативного применения оригинал документа

    3.22 напряжение номинальное (nominal voltage): Максимально приближенное значение напряжения, принятое для удобства обозначения и идентификации аккумулятора или батареи одной электрохимической системы.

    Источник: ГОСТ Р МЭК 62485-2-2011: Батареи аккумуляторные и установки батарейные. Требования безопасности. Часть 2. Стационарные батареи оригинал документа

    3.15 номинальное напряжение (nominal voltage): Соответствующее приблизительное значение напряжения, которое используют при проектировании или идентификации элемента, батареи или электрохимической системы.

    [IEV 482-03-31:2004]

    Источник: ГОСТ Р МЭК 60086-4-2009: Батареи первичные. Часть 4. Безопасность литиевых батарей оригинал документа

    3.10 номинальное напряжение (nominal voltage): Соответствующее приблизительное значение напряжения, которое используют для идентификации первичной батареи.

    Источник: ГОСТ Р МЭК 60086-5-2009: Батареи первичные. Часть 5. Безопасность батарей с водным электролитом оригинал документа

    Англо-русский словарь нормативно-технической терминологии > nominal voltage

  • 7 UN

    1. уникальный идентификатор предмета
    2. номинальное напряжение
    3. городская сеть

     

    городская сеть
    городская электросеть

    -
    [Лугинский Я. Н. и др. Англо-русский словарь по электротехнике и электроэнергетике. 2-е издание - М.: РУССО, 1995 - 616 с.]

    Тематики

    Синонимы

    EN

     

    номинальное напряжение
    Напряжение, установленное изготовителем для прибора
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    номинальное напряжение Uном, кВ
    Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
    [ ГОСТ Р 52726-2007]

    номинальное напряжение

    Un
    Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    rated voltage
    voltage assigned to the appliance by the manufacturer
    [IEC 60335-1, ed. 4.0 (2001-05)]

    rated voltage
    quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    rated voltage
    input or output supply voltage for which equipment is designed or specified
    [IEC 88528-11, ed. 1.0 (2004-03)]

    rated voltage
    specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
    NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    rated voltage
    the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
    NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    rated voltage
    reference voltage for which the cable is designed, and which serves to define the electrical tests
    NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
    Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
    U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
    In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
    This condition applies both to the value Uo and to the value U.
    In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
    NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
    [IEC 60245-1, ed. 4.0 (2003-12)]

    rated voltage
    highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
    [IEC 60800, ed. 3.0 (2009-07)]

    rated voltage
    the r.m.s. line-to-line voltage under rated conditions
    Primary side of input transformer: ULN
    Converter input: UVN
    Converter output: UaN
    Motor voltage: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    rated voltage
    input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
    [IEC 62040-1, ed. 1.0 (2008-06)]

    nominal voltage, Un
    voltage by which a system is designated or identified
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    tension assignée
    tension attribuée à l'appareil par le fabricant
    [IEC 60335-1, ed. 4.0 (2001-05)]

    tension nominale
    tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    tension assignée
    tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
    NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    tension assignée
    valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
    NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    tension assignée
    tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
    NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
    Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
    U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
    Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
    Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
    Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
    NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
    [IEC 60245-1, ed. 4.0 (2003-12)]

    tension assignée
    tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
    [IEC 60800, ed. 3.0 (2009-07)]

    tension assignée
    valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
    Primaire du transformateur d’entrée: ULN
    Entrée du convertisseur: UVN
    Sortie du convertisseur: UaN
    Moteur: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    tension assignée
    tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
    [IEC 62040-1, ed. 1.0 (2008-06)]

    tension nominale, Un
    tension par laquelle un réseau est désigné ou identifié
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    Синонимы

    • Un

    EN

    FR

    3.11 уникальный идентификатор предмета (unique item identifier; UN): Номер, используемый для уникальной идентификации отдельного предмета учета, действительный в течение всего срока его службы.

    Примечание 1 - В случае, если радиочастотная метка повторно используется для идентификации другого предмета, то ранее записанный на нее идентификатор предмета должен быть изменен.

    Примечание 2 - Уникальный идентификатор Министерства обороны США (DoD Unique Identifier) и электронный код продукции (ЕРС) являются разновидностями идентификатора предмета. Например, идентификатор GS1 SSCC является идентификатором предмета (Item ID; IID) с ограниченным сроком действия, идентификатор GS1 GRAI - идентификатором предмета для присвоения возвратным активам, GS1 sGTIN - идентификатором предмета для присвоения товарной продукции.

    Примечание 3 - Вместо термина «уникальный идентификатор предмета» не рекомендуется применять термин «уникальный идентификатор (UID)». То же самое относится к терминам «идентификатор микросхемы», «идентификатор радиочастотной метки» или «идентификатор объекта».

    Источник: ГОСТ Р ИСО/МЭК 15963-2011: Информационные технологии. Радиочастотная идентификация для управления предметами. Уникальная идентификация радиочастотных меток оригинал документа

    Англо-русский словарь нормативно-технической терминологии > UN

  • 8 design voltage

    1. номинальное напряжение

     

    номинальное напряжение
    Напряжение, установленное изготовителем для прибора
    [ ГОСТ Р 52161. 1-2004 ( МЭК 60335-1: 2001)]

    номинальное напряжение Uном, кВ
    Номинальное междуфазное напряжение электрической сети, для работы в которой предназначены коммутационные аппараты.
    [ ГОСТ Р 52726-2007]

    номинальное напряжение

    Un
    Напряжение, применяемое для обозначения или идентификации системы электроснабжения.
    [ ГОСТ Р 51317.4.30-2008 (МЭК 61000-4-30:2008)]

    EN

    rated voltage
    voltage assigned to the appliance by the manufacturer
    [IEC 60335-1, ed. 4.0 (2001-05)]

    rated voltage
    quantity value assigned, generally by the manufacturer, for a specified operating condition of a machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    rated voltage
    input or output supply voltage for which equipment is designed or specified
    [IEC 88528-11, ed. 1.0 (2004-03)]

    rated voltage
    specified value of the voltage at the terminals of the machine when operating at a rating. If unidirectional, the voltage is the arithmetic mean of the recurring waveform and if alternating it is the root mean square value of the fundamental frequency component of the recurring waveform
    NOTE - In the case of a machine with a protective resistor permanently in series, the resistor is considered as an integral part of the machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    rated voltage
    the value of voltage assigned by the manufacturer to a component, device or equipment and to which operation and performance characteristics are referred
    NOTE - Equipment may have more than one rated voltage value or may have a rated voltage range.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    rated voltage
    reference voltage for which the cable is designed, and which serves to define the electrical tests
    NOTE 1 - The rated voltage is expressed by the combination of two values: Uo/U expressed in volts (V):
    Uo being the r.m.s. value between any insulated conductor and "earth" (metal covering of the cable or the surrounding medium);
    U being the r.m.s. value between any two phase conductors of a multicore cable or of a system of single-core cables.
    In an alternating-current system, the rated voltage of a cable is at least equal to the nominal voltage of the system for which it is intended.
    This condition applies both to the value Uo and to the value U.
    In a direct current system, the nominal voltage of the system is not higher than 1,5 times the rated voltage of the cable.
    NOTE 2 - The operating voltage of a system may permanently exceed the nominal voltage of such a system by 10 %. A cable can be used at a 10 % higher operating voltage than its rated voltage if the latter is at least equal to the nominal voltage of the system
    [IEC 60245-1, ed. 4.0 (2003-12)]

    rated voltage
    highest allowable voltage between the conductors in a twin and multi conductor cable, or between one conductor and an electrical conductive screen, or between the two ends of a single core cable, or earth in unscreened cables
    [IEC 60800, ed. 3.0 (2009-07)]

    rated voltage
    the r.m.s. line-to-line voltage under rated conditions
    Primary side of input transformer: ULN
    Converter input: UVN
    Converter output: UaN
    Motor voltage: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    rated voltage
    input or output voltage (for three-phase supply, the phase-to-phase voltage) as declared by the manufacturer
    [IEC 62040-1, ed. 1.0 (2008-06)]

    nominal voltage, Un
    voltage by which a system is designated or identified
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    FR

    tension assignée
    tension attribuée à l'appareil par le fabricant
    [IEC 60335-1, ed. 4.0 (2001-05)]

    tension nominale
    tension assignée, généraleme<>value of voltage assigned by the manufacturer, to a componentnt par le constructeur pour des conditions spécifiées de fonctionnement de la machine
    [IEC 60034-18-41, ed. 1.0 (2006-10)]

    tension assignée
    tension spécifiée aux bornes de la machine quand celle-ci fonctionne au régime assigné. Dans le cas d'une tension redressée, sa valeur est égale à la valeur moyenne de l'onde périodique. Dans le cas d'une tension alternative, sa valeur est égale à la valeur efficace de la composante fondamentale de l'onde périodique
    NOTE - Dans le cas d'une machine équipée d'une résistance de protection connectée en permanence en série, la résistance est considérée comme faisant partie intégrante de la machine
    [IEC 60349-1, ed. 1.0 (1999-11)]

    tension assignée
    valeur de la tension, assignée par le constructeur à un composant, à un dispositif ou à un matériel, et à laquelle on se réfère pour le fonctionnement et pour les caractéristiques fonctionnelles
    NOTE - Les matériels peuvent avoir plusieurs valeurs ou une plage de tensions assignées.
    [IEC 62497-1, ed. 1.0 (2010-02)]

    tension assignée
    tension de référence pour laquelle le conducteur ou le câble est prévu et qui sert à définir les essais électriques
    NOTE 1 - La tension assignée est exprimée par la combinaison de deux valeurs Uo /U, exprimées en volts (V):
    Uo étant la valeur efficace entre l'âme d'un conducteur isolé quelconque et la «terre» (revêtement métallique du câble au milieu environnant);
    U étant la valeur efficace entre les âmes conductrices de deux conducteurs de phase quelconques d'un câble multiconducteur ou d'un système de câbles monoconducteurs ou de conducteurs.
    Dans un système à courant alternatif, la tension assignée d'un conducteur ou d’un câble est au moins égale à la tension nominale du système pour lequel il est prévu.
    Cette condition s'applique à la fois à la valeur Uo et à la valeur U.
    Dans un système à courant continu, la tension nominale admise du système n’est pas supérieure à 1,5 fois la tension assignée du conducteur ou du câble.
    NOTE 2 - La tension de service d'un système peut en permanence dépasser la tension nominale dudit système de 10 %. Un conducteur ou un câble peut être utilisé à une tension de service supérieure de 10 % à sa tension assignée si cette dernière est au moins égale à la tension nominale du système
    [IEC 60245-1, ed. 4.0 (2003-12)]

    tension assignée
    tension maximale admissible entre les âmes dans un câble ayant une paire ou multi conducteur ou entre une âme et un écran conducteur électrique ou avec la terre pour un câble non écranté ou encore entre les deux extrémités d’un câble à âme unique
    [IEC 60800, ed. 3.0 (2009-07)]

    tension assignée
    valeur efficace de la tension de ligne (entre phases) dans les conditions assignées
    Primaire du transformateur d’entrée: ULN
    Entrée du convertisseur: UVN
    Sortie du convertisseur: UaN
    Moteur: UAN
    [IEC 61800-4, ed. 1.0 (2002-09)]

    tension assignée
    tension d’alimentation d’entrée ou de sortie (dans le cas d’une alimentation triphasée, tension entre phases) déclarée par le constructeur
    [IEC 62040-1, ed. 1.0 (2008-06)]

    tension nominale, Un
    tension par laquelle un réseau est désigné ou identifié
    [IEC 61000-4-30, ed. 2.0 (2008-10)]

    Тематики

    Синонимы

    • Un

    EN

    FR

    3.7 номинальное напряжение (design voltage): Объявленное изготовителем напряжение, к которому относятся все характеристики устройства управления лампами и которое должно быть не менее 85 % наибольшего значения диапазона нормируемого напряжения.

    Источник: ГОСТ Р МЭК 61347-1-2011: Устройства управления лампами. Часть 1. Общие требования и требования безопасности оригинал документа

    Англо-русский словарь нормативно-технической терминологии > design voltage

См. также в других словарях:

  • ГОСТ Р МЭК 60204-1-2007: Безопасность машин. Электрооборудование машин и механизмов. Часть 1. Общие требования — Терминология ГОСТ Р МЭК 60204 1 2007: Безопасность машин. Электрооборудование машин и механизмов. Часть 1. Общие требования оригинал документа: TN систем питания Испытания по методу 1 в соответствии с 18.2.2 могут быть проведены для каждой цепи… …   Словарь-справочник терминов нормативно-технической документации

  • 29.160.01 — Машины вращающиеся в целом ГОСТ 2.722 68 ГОСТ 2.726 68 ГОСТ 4.154 85 ГОСТ 4.167 85 ГОСТ 4.330 85 ГОСТ 2479 79 ГОСТ 2582 81 ГОСТ 4541 70 ГОСТ 8592 79 …   Указатель национальных стандартов 2013

  • ГОСТ 28173-89 — (МЭК 34 1 83) Утратил силу в РФ Пользоваться: ГОСТ Р 52776 2007 (МЭК 60034 1:2004) …   Указатель национальных стандартов 2013

  • ГОСТ 183-74 — Утратил силу в РФ Пользоваться: ГОСТ Р 52776 2007 (МЭК 60034 1:2004) …   Указатель национальных стандартов 2013

  • ГОСТ Р 52776-2007 — (МЭК 60034 1:2004) 74 с. (11) Машины электрические вращающиеся. Номинальные данные и характеристики раздел 29.160.01 …   Указатель национальных стандартов 2013

  • коэффициент циклической продолжительности включения — ГОСТ Р 52776 2007 (МЭК 60034 1 2004) EN cyclic duration factor the ratio between the period of loading, including starting and electric braking, and the duration of the duty cycle, expressed as a percentage [IEV number 411 51 09] FR facteur de… …   Справочник технического переводчика

  • Общее — F.1. Общее В настоящем стандарте приводится большое число общих требований, которые могут или не могут быть применены в отношении отдельной машины. Поэтому простое, без квалифицированной оценки утверждение о соответствии оборудования всем… …   Словарь-справочник терминов нормативно-технической документации

  • номинальный — 3.7 номинальный: Слово, используемое проектировщиком или производителем в таких словосочетаниях, как номинальная мощность, номинальное давление, номинальная температура и номинальная скорость. Примечание Следует избегать использования этого слова …   Словарь-справочник терминов нормативно-технической документации

  • защита — 3.25 защита (security): Сохранение информации и данных так, чтобы недопущенные к ним лица или системы не могли их читать или изменять, а допущенные лица или системы не ограничивались в доступе к ним. Источник: ГОСТ Р ИСО/МЭК 12207 99:… …   Словарь-справочник терминов нормативно-технической документации

  • метод — метод: Метод косвенного измерения влажности веществ, основанный на зависимости диэлектрической проницаемости этих веществ от их влажности. Источник: РМГ 75 2004: Государственная система обеспечения еди …   Словарь-справочник терминов нормативно-технической документации

  • Номинальная мощность — 4а. Номинальный ток светового прибора Ток, указанный изготовителем на световом приборе Источник: ГОСТ 16703 79: Приборы и комплексы световые. Термины и определения оригинал документа …   Словарь-справочник терминов нормативно-технической документации

Поделиться ссылкой на выделенное

Прямая ссылка: